Akubarik Exakt

From LinnDocs
Revision as of 15:07, 10 June 2014 by Yoda (talk | contribs)
Jump to: navigation, search

Operation

General

If the Exakt DSM is in Standby, the Akubarik speaker is totally shutdown. No LED's or indicators are shown


Image:AkubarikE_ON.jpg

When the Exakt DSM is brought out of Standby it will send trigger voltage and wake the speaker up. The LED's beside the Mains socket/Exakt link sockets will tell you the status. After approx 6seconds the Blue LED on the top of the speaker will illuminate stating "its ready to party!"


Signal sensing

Image:Akubarik_blue_leds.jpg

When an input signal is detected, the Chakra amplifier is enabled and the blue LED lights (red LED goes off). In the absence of an audio signal, the amplifier reverts to a sleep mode after approximately 20 minutes.


Protection

Operation

If an amplifier channel overheats or detects an overload condition, the power supply for that channel will shut down in order to protect the amplifier and the loudspeaker drive unit(s) to which it is connected.

Image:Akubarik_blue_and_red_leds.jpg

Duration

Once the condition that caused the amplifier to activate its protection has passed, the amplifier will automatically resume normal operation. How long the channels remain in protection will depend on the cause. If the protection operates for more than a few seconds, it could indicate overheating which may take some minutes of cooling to rectify.