Difference between revisions of "TroubleShooting:Selekt DSM"

From LinnDocs
Jump to: navigation, search
m (Selekt DSM does not product any sound/music from the cartridge(s))
m (Selekt DSM does not product any sound/music from the cartridge(s))
Line 6: Line 6:
 
::a) In the Speakers configuration box select the <span style="color:#FFFFFF;background:#000080;padding:3px"><b> FALLBACK </b></span> button. This will put the Selekt cartridge backplane into software FALLBACK mode.
 
::a) In the Speakers configuration box select the <span style="color:#FFFFFF;background:#000080;padding:3px"><b> FALLBACK </b></span> button. This will put the Selekt cartridge backplane into software FALLBACK mode.
 
::b) After a few moment press the <span style="color:#FFFFFF;background:#000080;padding:3px"><b>RESTORE</b></span>  button on the Speaker configuration page.
 
::b) After a few moment press the <span style="color:#FFFFFF;background:#000080;padding:3px"><b>RESTORE</b></span>  button on the Speaker configuration page.
::c) Let it go through it’s steps.  
+
::c) Let it go through its steps.  
:3. When its finished power cycle the Selekt set up the speaker info and see if normal operation has returned.
+
:3. When it's finished, power cycle the Selekt, set up the speaker info and see if normal operation has returned.
  
  

Revision as of 07:52, 24 October 2022

Selekt DSM issues

Selekt DSM does not product any sound/music from the cartridge(s)

Using Konfig
1. Make sure that your Selekt DSM is powered on and your LAN network has Ethernet access
2. In Konfig select you DSM and go into the Exakt or Speakers tab
a) In the Speakers configuration box select the FALLBACK button. This will put the Selekt cartridge backplane into software FALLBACK mode.
b) After a few moment press the RESTORE button on the Speaker configuration page.
c) Let it go through its steps.
3. When it's finished, power cycle the Selekt, set up the speaker info and see if normal operation has returned.


If this does not work
1. Power down the Selekt,
2. REMOVE any fitted cartridges,
3. Power up the Selekt,
4. When booted up go into the Exakt tab in Konfig and click on the RESTORE button. This will reflash the Backplane board software.
5. Power down the Selekt,
6. REFIT any fitted cartridges,
7. Power up and all should now be working. If not please contact Linn Helpline.