OPTION Settings Description Default Setting
Selection Timeout 1 - 10 seconds Allows you to adjust the time taken for source selection to take effect. A delay allows you time to scroll through and view available sources. 1 second
Startup Source None

Last Used

Aux

Phono

Input 5

Input 4

Input 3

Input 2

Majik CD

Allows you to set which source input will be selected when the unit comes out of standby.

Note: The names shown are configured in the Source Configuration options.

Last Used
Standby Record From None

Last Used

Aux

Phono

Input 5

Input 4

Input 3

Input 2

Majik CD

Allows you to set a source to be output at TAPE OUT while the unit is in standby.

Note: The names shown are configured in the Source Configuration options.

Last Used
Handset Commands Enabled

Disabled

If set to Enable, the unit will accept remote commands from the handset.

If set to Disabled, the unit will not accept remote commands from the handset. (Setup menus will only be accessible and adjustable via the front panel controls.)

Enabled
RS232 Configuration N/A This option accesses the RS232 setup sub-menu – used to configure the unit to communicate with other RS232 enabled products.
Unit Defaults N/A This option accesses the defaults sub-menu – used for saving and recalling configurations. N/A
Unit Information N/A Not adjustable – for information only. Allows the unit’s software/hardware revisions to be viewed. This category is mainly intended for Linn personnel and Linn-appointed service agents. N/A