| width =150 | <B>Linn Network</b>
+
| width =150 style="color:blue" | <B><u>Linn Network</u></b>
| width =100| ||
+
| width =100 style="color:black"| ||
 
|-  
 
|-  
 
||
 
||
Line 28: Line 28:
 
|| || || 32767 || Fully initialised and operational.
 
|| || || 32767 || Fully initialised and operational.
 
|-
 
|-
 
+
|| || || ||<br>
 +
|-
 +
||
 +
| style="color:blue" | <B><u>Linn DS Series</u></b>
 +
| style="color:black"|
 +
||
 +
|-
 +
||
 +
|colspan = "3" |The driver has the following read-only variables in addition to the standard variables defined by Control4:
 +
|
 +
|-
 +
|| ||<b><u>Variable</u></b>
 +
|colspan="2"|<b><u>Purpose</u></b>
 +
|- 
 +
||
 +
||<b>INPUT_NUMBER    </b>
 +
|colspan = "2"| Indicates which input is currently supplying audio to the room output:
 +
||
 +
|-
 +
|| || || -2 || Songcast from a remote streamer.
 +
|-
 +
|| || || -1 || The local streamer.(Playlist/Radio)
 +
|-
 +
|| || || 0 || Nothing
 +
|-
 +
|| || || 1..32 || External input 1..32; see Properties to determine which input number corresponds to which input device.
 +
|-
 +
|| ||
 +
|colspan="2"| Note that it is not guaranteed that the input number is 0 when the room is off, so programming should not rely on this nor on receiving a change in this value when the room switches on.
 +
|- 
 +
||
 +
||<b>INPUT_NUMBER    </b>
 +
|colspan = "2"| Indicates which input is currently supplying audio to the room output:
 +
||
 +
|-
 
|)
 
|)

Revision as of 11:50, 5 August 2021

Variable Summary
Linn Network
The driver has the following read-only variables in addition to the standard variables defined by Control4:
Variable Purpose
CONNECT_STATE Indicates the state of the connection from the driver to the Kazoo server gateway:
0 Not connected.
1 Connecting.
2 Connected.
32767 Fully initialised and operational.

Linn DS Series
The driver has the following read-only variables in addition to the standard variables defined by Control4:
Variable Purpose
INPUT_NUMBER Indicates which input is currently supplying audio to the room output:
-2 Songcast from a remote streamer.
-1 The local streamer.(Playlist/Radio)
0 Nothing
1..32 External input 1..32; see Properties to determine which input number corresponds to which input device.
Note that it is not guaranteed that the input number is 0 when the room is off, so programming should not rely on this nor on receiving a change in this value when the room switches on.
INPUT_NUMBER Indicates which input is currently supplying audio to the room output:
)