Difference between revisions of "Klimax Renew DS"

From LinnDocs
Jump to: navigation, search
(Created page with "right|435x143px == '''Product info''' == * ''Product Name:'' Renew DS * ''Date of Introduction:'' May 2011 * ''Type:'' Digital music player * ''F…")
 
m (Network Setup)
(9 intermediate revisions by 2 users not shown)
Line 12: Line 12:
 
** [http://docs.linn.co.uk/wiki/index.php/Why_Linn_DS_is_the_best_way_to_play_CDs DS Design]
 
** [http://docs.linn.co.uk/wiki/index.php/Why_Linn_DS_is_the_best_way_to_play_CDs DS Design]
 
** [http://docs.linn.co.uk/wiki/index.php/Dynamik Dynamik Power Supply]
 
** [http://docs.linn.co.uk/wiki/index.php/Dynamik Dynamik Power Supply]
 +
 +
* ''Purpose''
 +
:The Klimax Renew DS was used with upgrades of existing Klimax DS products to a newer variant of this product. The circuit board that was removed from the Klimax DS was offered as an ''Renew'' package. This Klimax Renew DS has a power supply, case and ID circuit board to match the original circuit board with its new serial number.<br>
 +
:This Renew option saves on the disposal of the original circuit board and helps to save the Environment.
  
 
== '''Support''' ==
 
== '''Support''' ==
Line 19: Line 23:
 
== '''Latest software''' ==
 
== '''Latest software''' ==
  
[http://www.linn.co.uk/ds_software Latest software releases]
+
{{General:Latest_Product_SW}}
 
 
[http://oss.linn.co.uk/trac Open source software]
 
  
 
== '''Manuals''' ==
 
== '''Manuals''' ==
Line 27: Line 29:
 
[http://small.linncdn.com/product-catalogue/documents/Linn_Klimax_DS_Quickstart.pdf Product Information / Quickstart Guide (for KlimaxDS)]
 
[http://small.linncdn.com/product-catalogue/documents/Linn_Klimax_DS_Quickstart.pdf Product Information / Quickstart Guide (for KlimaxDS)]
  
[http://docs.linn.co.uk/wiki/index.php/Linn_Konfig_Manual Konfig manual]
+
{{General:Product_Manuals}}]
 
 
[http://oss.linn.co.uk/trac/wiki/KinskyDesktopManual Kinsky Desktop manual]
 
 
 
[http://docs.linn.co.uk/wiki/index.php/DS_&_REM_019 Remote Control manual]
 
 
 
[http://oss.linn.co.uk/trac/wiki/KinskyJukeboxManual Kinsky Jukebox manual]
 
 
 
[http://docs.linn.co.uk/wiki/images/1/1b/Linn_Safety_Info.pdf Safety Information]
 
 
 
[http://www.linn.co.uk/warranty Warranty Terms and Conditions]
 
  
 
== '''Network Setup''' ==
 
== '''Network Setup''' ==
  
[[DS Budget System| DS Budget System Setup]]
+
{{General:DS_Network_system}}
 
 
[[DS Entry Level System| DS Entry Level System Setup]]
 
 
 
[[DS High End System| DS High End System Setup]]
 
  
 
== '''Back Panel Connections''' ==
 
== '''Back Panel Connections''' ==
Line 51: Line 39:
 
[[Image:Klimax DS rear.jpg|center|700x241px|Image:Klimax_DS_rear.jpg]] <br>
 
[[Image:Klimax DS rear.jpg|center|700x241px|Image:Klimax_DS_rear.jpg]] <br>
  
# '''MAINS INPUT''' - For connection to the mains supply.
+
# {{link:MAINS INPUT}}
 
# '''POWER SWITCH'''- For switching the power to the unit on and off
 
# '''POWER SWITCH'''- For switching the power to the unit on and off
# '''ETHERNET''' - For connecting the unit to the network.
+
# {{link:ETHERNET}}
 
# '''RS232 PORTS''' - For connection to Linn source products without ethernet ports. Please note: Early versions on the Renew DS has RS232 port 1 & 2 labels swopped around. If you have any difficulty, please test this connection using the Konfig-Diagnostics
 
# '''RS232 PORTS''' - For connection to Linn source products without ethernet ports. Please note: Early versions on the Renew DS has RS232 port 1 & 2 labels swopped around. If you have any difficulty, please test this connection using the Konfig-Diagnostics
# '''FALLBACK''' - Used when reprogramming the unit.
+
# {{link:FALLBACK}}
 
# '''EARTH GROUND''' - For connecting the unit to an earthing terminal if no mains earth is available or for joining the earths of other products in the system to improve perfromance in areas of poor/noisy electrical earth conditions.
 
# '''EARTH GROUND''' - For connecting the unit to an earthing terminal if no mains earth is available or for joining the earths of other products in the system to improve perfromance in areas of poor/noisy electrical earth conditions.
 
# '''UNBALANCED OUT RIGHT, LEFT''' - To connect to a preamplifier (or power amplifier when internal volume control is enabled) with unbalanced (RCA) analogue inputs.
 
# '''UNBALANCED OUT RIGHT, LEFT''' - To connect to a preamplifier (or power amplifier when internal volume control is enabled) with unbalanced (RCA) analogue inputs.
Line 76: Line 64:
 
* [http://docs.linn.co.uk/wiki/index.php/product_positioning Positioning Information]
 
* [http://docs.linn.co.uk/wiki/index.php/product_positioning Positioning Information]
  
For further assistance, try our [http://www.linn.co.uk/linn_customer_support customer support] pages or the [http://Forums.linn.co.uk Linn Forum.]
+
For further assistance, try our [http://www.linn.co.uk/linn_customer_support customer support] pages
 +
[[Category:Linn_DS]]

Revision as of 15:20, 20 November 2020

RenewDsDevice.png

Product info

  • Product Name: Renew DS
  • Date of Introduction: May 2011
  • Type: Digital music player
  • Purpose
The Klimax Renew DS was used with upgrades of existing Klimax DS products to a newer variant of this product. The circuit board that was removed from the Klimax DS was offered as an Renew package. This Klimax Renew DS has a power supply, case and ID circuit board to match the original circuit board with its new serial number.
This Renew option saves on the disposal of the original circuit board and helps to save the Environment.

Support

Linn Support Site

Latest software

Latest software releases

Details of latest Product release software

Manuals

Product Information / Quickstart Guide (for KlimaxDS)

Controlling the product User Guide

Product setup:Manage Systems user manual

Space Optimisation (Advanced)

Safety Information

Warranty Terms and Conditions

Third Party Software Copyright]

Network Setup

Back Panel Connections

Image:Klimax_DS_rear.jpg


  1. MAINS INPUT - To connect to the mains electricity supply.
  2. POWER SWITCH- For switching the power to the unit on and off
  3. ETHERNET - To connect to a network (100Base-T)
  4. RS232 PORTS - For connection to Linn source products without ethernet ports. Please note: Early versions on the Renew DS has RS232 port 1 & 2 labels swopped around. If you have any difficulty, please test this connection using the Konfig-Diagnostics
  5. FALLBACK - To put the device into Fallback mode (used when reprogramming)
  6. EARTH GROUND - For connecting the unit to an earthing terminal if no mains earth is available or for joining the earths of other products in the system to improve perfromance in areas of poor/noisy electrical earth conditions.
  7. UNBALANCED OUT RIGHT, LEFT - To connect to a preamplifier (or power amplifier when internal volume control is enabled) with unbalanced (RCA) analogue inputs.
  8. BALANCED OUT RIGHT, LEFT - To connect to a preamplifier (or power amplifier when internal volume control is enabled) with balanced (XLR) analogue inputs.


Front Panel Connections

Image:RenewDsDevice.png


Installation

Please read the following carefully before installing the unit in your system – your unit may need to be reconfigured by your Linn retailer.

For further assistance, try our customer support pages