Cables & terminations
The typical termination standard between Linn products are:
RCA/Phono
- Inputs
Input sensitivity: | Selectable: 1 / 2 / 4 Vrms | |
Input impedance: | typically 10 kΩ |
- Outputs
Analogue Output: | 2 Vrms | |
Output Impedance: | 300 Ω | |
RCA Output Coupling: | Transformer - Klimax DS/1 onwards and all Klimax DSM | |
Direct - all other products |
XLR
- Inputs
Input sensitivity: | Selectable: 2 / 4 / 8 Vrms | |
Input impedance: | 7.8kΩ | |
XLR Coupling: | Direct (some Klimax products have the option of Transformer or Direct) |
- Outputs
Analogue Output: | 4 Vrms | |
Output Impedance: | 300 Ω | |
XLR Output Coupling: | Direct - Majik/Akurate/Selekt | |
Transformer - Klimax |
- XLR pin outs
- 1 - Sheild
- 2 - HOT (white)
- 3 - COLD (Blue)
- Converting XLR to/from Phono/RCA
SPDIF
- Inputs
Input voltage | 0.3V (when terminated with 75Ω ) | |
Input impedance: | 75Ω |
- Outputs
Min Input voltage | 0.5V rms (when terminated with 75Ω ) | |
Input impedance: | 75Ω |
Exakt Cables
ALL FOUR pairs of the cables are used in the Exakt-Link cable. This is NOT an ethernet transport cable but an Exakt transport cable. These pairs are used to transmit the audio data, power triggers and a master timing control to ensure that the audio from all channels are in perfect sync.
The Exakt-link has been designed to operate with the CAT-5 cable electrical specifications for signal timings. There have been NO changes to this design for any other CAT cable standards. (updated 2019)
- We recommend using the 100Base-T4 / 568B ethernet cable pairing
- Exakt Link uses readily available network cables:
- CAT 5/5e UTP/FTP
- CAT 6/6a UTP/FTP
- Note: There is no change in the audio performance of the Exakt Link between Cat 5 or Cat 6 Cables.
Cat-7 and Cat-8 cables may not work well with an Exakt system. For a trouble-free, reliable, high performance installation, we recommend use of Cat 5 or Cat 6.
Typical Ethernet 100Base-T length restrictions guide:
- Patch cable < 30M
- Solid core cable < 100M
EXAKT-LINK CANNOT be used with:
- Ethernet Network Routers,
- Ethernet Network Switches,
- Ethernet Isolators,
- Ethernet conditioners,
- HomePlugs/Ethernet-over-Mains devices
- WLAN bridges etc
Exakt-Link can ONLY be a CAT5/6 cable from Exakt socket to Exakt socket
EXAKT LINK terminations
- The cables are paired up using OUT > IN style connections.
- Any Linn product with these sockets can be linked together. This means you can link a Klimax DS/2 to a Majik ExaktBox-I and have a fully working Exakt system